Honda Environmental Annual Report 2006 Top

Quality Innovation Center Tochigi

Address
52-1 Hagadai, Haga Machi, Haga Gun, Tochigi Prefecture
Established
April 2003
Major Responsibilities
Responses to quality issues in the market
Employment
478 associates (as of March 31, 2006)
Water discharge point
Nomoto River via Haga Industrial Park Treatment Center

Water Quality
Item Unit Regulation Standards (Incl. Agreed Standards) Voluntary Regulation Standards Measurement Results
Maximum (minimum) Average
Hydrogen ion concentration
pH 5.8–8.6 5.8–8.6 7.7 (7.0) 7.4
Biochemical oxygen demand (BOD)
mg/L 25 12.5 4.6 (Less than 0.5) 1.3
Chemical oxygen demand (COD)
mg/L 25 12.5 8.3 (1.7) 4.6
Suspended solids (SS)
mg/L 50 25 3.4 (Less than 0.5) 1.3
Oil content
mg/L 5 2.5 0.9 (0) 0.2
Phenols
mg/L 1 0.5 Less than 0.05 Less than 0.05
Copper and its compounds
mg/L Should not be detected Undetected Undetected Undetected
Zinc and its compounds
mg/L 5 2.5 0.07(0.05) 0.1
Soluble iron and its compounds
mg/L 3 1.5 0.12 (Less than 0.05) Less than 0.05
Soluble manganese and its compounds
mg/L 3 1.5 Less than 0.01 Less than 0.01
Total chromium
mg/L 2 1 Less than 0.02 Less than 0.02
Fluorine content
mg/L 8 6.5 Less than 0.02 Less than 0.02
Colon bacillus colony count
No./cm3 3,000 1,500 59 (0) 8.5
Nitrogen content
mg/L 20 10 7.8(1.3) 4.6
Phosphorous content
mg/L 2 1 0.09 (Less than 0.05) Less than 0.1
Cadmium and its compounds
mg/L Should not be detected Undetected Undetected Undetected
Cyanides
mg/L Should not be detected Undetected Undetected Undetected
Organic phosphorus compounds
mg/L Should not be detected Undetected Undetected Undetected
Lead and its compounds
mg/L Should not be detected Undetected Undetected Undetected
Chromium (VI) compounds
mg/L Should not be detected Undetected Undetected Undetected
Arsenic and its compounds
mg/L Should not be detected Undetected Undetected Undetected
Mercury and its compounds
mg/L Should not be detected Undetected Undetected Undetected
Alkyl mercury and its compounds
mg/L Should not be detected Undetected Undetected Undetected
PCB
mg/L Should not be detected Undetected Undetected Undetected
Trichloroethylene
mg/L Should not be detected Undetected Undetected Undetected
Tetrachloroethylene
mg/L Should not be detected Undetected Undetected Undetected
Dichloromethane
mg/L 0.2 0.1 Less than 0.002 Less than 0.002
Tetrachloride carbon
mg/L 0.02 0.01 Less than 0.001 Less than 0.001
1,2-dichloroethane
mg/L 0.04 0.02 Less than 0.0004 Less than 0.0004
1,1-dichloroethylene
mg/L 0.2 0.1 Less than 0.002 Less than 0.002
Cis-1,2-dichloroethylene
mg/L 0.4 0.2 Less than 0.004 Less than 0.004
1,1,1-trichloroethane
mg/L Should not be detected Undetected Undetected Undetected
1,1,2-trichloroethane
mg/L 0.06 0.03 Less than 0.0006 Less than 0.0006
1,3-dichloropropane
mg/L 0.02 0.01 Less than 0.002 Less than 0.002
Thiram
mg/L 0.06 0.03 Less than 0.001 Less than 0.001
Simazine
mg/L 0.03 0.015 Less than 0.001 Less than 0.001
Thiobencarb
mg/L 0.2 0.1 Less than 0.002 Less than 0.002
Benzene
mg/L 0.1 0.05 Less than 0.001 Less than 0.001
Selenium and its compounds
mg/L 0.1 0.05 Less than 0.01 Less than 0.01

Air Quality
Item Unit Regulation Standards (Incl. Agreed Standards) Voluntary Regulation Standards Measurement Results
Maximum (minimum) Average
Particulates
g/Nm3 0.3 0.15 Less than 0.005 Less than 0.005
Nitrogen oxides
ppm 180 90 59.5 41.4
Sulphur oxides
K value 7 3.5 Less than 0.01 Less than 0.01

PRTR Listed Substances
(Unit: kg)
Substance Volume Handled Volume Discharged Volume Transferred Recycling Volume 100 Disposed Volume Consumed (Transferred to Products)
Atmosphere Public Waters Sewage Waste Disposal Sites Outside Company
Xylene
4,463 900 0 0 0 0 1,609 1,954
Toluene
7,612 1,879 0 0 0 0 2,427 3,306
Total
12,075 2,779 0 0 0 0 4,036 5,260

Noise
Time zone Unit Regulation Standards (Incl. Agreed Standards) Voluntary Regulation Standards Measurement Results
(Maximum )
Morning and evening
dB 60 60 52
Afternoon
dB 65 65 55
Night
dB 50 50 49
Note: Regulation standard based on the pollution prevention ordinance of Tochigi Prefecture

Vibration
Time zone Unit Regulation Standards (Incl. Agreed Standards) Voluntary Regulation Standards Measurement Results
(Maximum )
Afternoon
dB 65 65 54 or less
Night
dB 60 60 46 or less
Note: Regulation standard based on the pollution prevention ordinance of Tochigi Prefecture

Odor
Item Unit Regulation Standards Voluntary Regulation Standards Measurement Results
(Maximum )
Methyl mercaptan
ppm 0.002 0.002 Less than 0.001
Hydrogen sulfide
ppm 0.02 0.02 Less than 0.002
Methyl sulfide
ppm 0.01 0.01 Less than 0.001
Methyl disulfide
ppm 0.009 0.009 Less than 0.001
Trimethylamine
ppm 0.005 0.005 Less than 0.001
Ammonia
ppm 1 1 Less than 0.1
Propionaldehyde
ppm 0.05 0.05 Less than 0.005
Normal butylaldehyde
ppm 0.009 0.009 Less than 0.003
Isobutyl aldehyde
ppm 0.02 0.02 Less than 0.003
Normal valeraldehyde
ppm 0.009 0.009 Less than 0.003
Isovaleraldehyde
ppm 0.003 0.003 Less than 0.003
Isobutanol
ppm 0.9 0.9 Less than 0.09
Ethyl acetate
ppm 3 3 Less than 0.3
Toluene
ppm 10 10 Less than 1
Xylene
ppm 1 1 Less than 0.1
Methyl isobutyl ketone
ppm 1 1 Less than 0.1
Styrene
ppm 0.4 0.4 Less than 0.04
Acetaldehyde
ppm 0.05 0.05 Less than 0.005

Home > About Honda > Environment

Honda Worldwide site
Home | Site Map | Site Index
About this Site